You are currently visiting the test version of the radboud Dspace repository. To access the production instance, you can navigate to: https://repository.ubn.ru.nl
Publication year
2015Author(s)
Source
AJNR American Journal of Neuroradiology, 36, 1, (2015), pp. 98-107ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Neurosurgery
Journal title
AJNR American Journal of Neuroradiology
Volume
vol. 36
Issue
iss. 1
Page start
p. 98
Page end
p. 107
Subject
Radboudumc 0: Other Research RIHS: Radboud Institute for Health SciencesAbstract
BACKGROUND AND PURPOSE: Incomplete occlusion and recanalization of large and wide-neck brain aneurysms treated by endovascular therapy remains a challenge. We present preliminary clinical and angiographic results of an experimentally optimized Surpass flow diverter for treatment of intracranial aneurysms in a prospective, multicenter, nonrandomized, single-arm study. MATERIALS AND METHODS: At 24 centers, 165 patients with 190 intracranial aneurysms of the anterior and posterior circulations were enrolled. The primary efficacy end point was the percentage of intracranial aneurysms with 100% occlusion on 6-month DSA. The primary safety end point was neurologic death and any stroke through a minimum follow-up of 6 months. RESULTS: Successful flow-diverter delivery was achieved in 161 patients with 186 aneurysms (98%); the mean number of devices used per aneurysm was 1.05. Clinical follow-up (median, 6 months) of 150 patients (93.2%), showed that the primary safety end point occurred in 18 subjects. Permanent neurologic morbidity and mortality were 6% and 2.7%, respectively. Morbidity occurred in 4% and 7.4% of patients treated for aneurysms of the anterior and posterior circulation, respectively. Neurologic death during follow-up was observed in 1.6% and 7.4% of patients with treated intracranial aneurysms of the anterior and posterior circulation, respectively. Ischemic stroke at </=30 days, SAH at </=7 days, and intraparenchymal hemorrhage at </=7 days were encountered in 3.7%, 2.5%, and 2.5% of subjects, respectively. No disabling ischemic strokes at >30 days or SAH at >7 days occurred. New or worsening cranial nerve deficit was observed in 2.7%. Follow-up angiography available in 158 (86.8%) intracranial aneurysms showed 100% occlusion in 75%. CONCLUSIONS: Clinical outcomes of the Surpass flow diverter in the treatment of intracranial aneurysms show a safety profile that is comparable with that of stent-assisted coil embolization. Angiographic results showed a high rate of intracranial aneurysm occlusion.
This item appears in the following Collection(s)
- Academic publications [244578]
- Faculty of Medical Sciences [92890]
Upload full text
Use your RU or RadboudUMC credentials to log in with SURFconext to upload a file for processing by the repository team.